Micromodule S2266 Two-Load Lamp Micro Module (Any Panel/2wires).
Technical Specifications * Rating Voltage 230VAC±10%, 50Hz * Lamp Load ≤400W * Standby power consumption <1W * Operating Temperature -10 to 50degC
Features * Hide behind any wall switch panel. * No need for ‘Neutral’ wire connection. * Can be used for incandescent and halogen lamp. * Cannot be used with fluorescent or PLC lamps as these require neutral wire connection. * Accepts 16 X10 addresses simultaneously. Useful for scenes control. * Easy set-up and operate. Electronic setup for address codes. * Built-in powerline ‘noise filter’ and high X10 signal sensitivity (25mV) * Fully compatible to any X10 controllers.
Set-Up * Shut off the electrical power. * Connects “L” to the incoming ‘Live’ wire and “1 and 2” to the two lamp circuits. * Connects the red and black wires to the existing switches (see Manual).
Single Address Settings: * Press and hold the setup button for 5 seconds & the light indicator will flicker once. * Release the setup button and the light indicator and the load will remain ‘On’ to indicate that you are now in the ‘program mode’. * Use any X10 controller and transmit the X10 address to the micro module e.g. send “A2 ON”. * Both the lamp indicator and the Lamp will now turn OFF to indicate that the address has been set. * The Micro Module will exit the ‘program mode’ if no action is taken after 8 seconds.
16 Addresses – Scene Controls Setting: Example: to set a Scene call ‘P1’ comprising Lamp A1-ON, A3-ON and B5-ON: * Switch ON lamps A1, A3 and B5. * Use any X10 Controller and send the following in sequence: M16-ON, N16-ON, O16-ON, P16-ON. Lamps A1, A3 and B5 will turn OFF momentarily and brighten again, indicating that you are now in the ‘Program Mode’. * Next transmit the X10 scene address that you want these 3 lamps to response to, i.e. ‘P1-ON’
To Delete Scene Address: Example: To delete A1 and A3 from Scene P1 but leave B5-ON: * Switch ON lamps A1 and A3. * Transmit the following sequence: O16-ON, P16-ON, M16-ON, N16-ON. (Note the difference in the two sequences.) * Lamps A1 and A3 will turn OFF momentarily and brightened again. * Now transmit ‘P1-ON’ and you are set. The next time you press ‘P1-ON’, only B5 will turn ON now.
To Delete All Scene Addresses: * Press and hold the Setup button for 12 seconds and all the scene addresses will be cleared completely.
Applications * Use in conjunction with your favourite designer switches to retain switches uniformity through out your house. * Response to ‘ON/OFF’, ‘All Lights ON/ All Units OFF commands. * Dimming controls possible with any X10 controllers. (Cannot be dimmed from the wall switch. * Only incandescent or halogen lamps are dimmable.
Notes: If only one lamp is used, please connect the black and red wires to the switch and ‘1’ to the lamp. Alternatively, you can also connectsthe black and blue wires to the switch and ‘2’ to the lamp.
You can not use this product in combination with halogen lighning, because it is a 2-wire module.
Modules and sets from S10 will be deliverd with a manual in the Englisch language. The modules are 100% compatible with other european X10 modules.
|